XLPO Insulated Wire and Cable Manufacturer

Home / Cable&Wire / Electrical Equipment Cables / Cross-linked Polyolefin (XLPO) Insulated Wire and Cable (Rated Voltage 450/750V and below)

  • Cross-linked Polyolefin (XLPO) Insulated Wire and Cable (Rated Voltage 450/750V and below)
  • Product Details

Product Standards
The development and production of this series strictly adhere to the following technical specifications and standards to ensure full compliance with industry entry requirements:

Industry Standard: JB/T 10491-2022 (Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V).
Enterprise Specification: Q/320282 GAD082-2022 (if applicable, please remove this line if not relevant).

Product Structure and Material Characteristics
High-Quality Conductor: Utilises high-purity electrical-grade annealed copper wire (or tinned copper wire). The DC resistance of the conductor is strictly controlled to ensure superior conductivity and minimise energy loss during operation.
XLPO Insulation Layer: Once cross-linked, the insulation material exhibits exceptional creep resistance, environmental stress cracking resistance (ESCR), and enhanced physical mechanical strength.
Scientifically Engineered Design: Across various models (such as WDZ-BYJ and WDZ-RYJR), the design prioritizes precise conductor arrangement and uniform insulation thickness to guarantee consistent electrical performance and long-term reliability.

Operating Characteristics & Performance Advantages
Multi-Level Thermal Ratings: The maximum continuous operating temperature of the conductor is available in four grades: 90°C, 105°C, 125°C, and 150°C, allowing for stable operation under diverse heat-load environments.
Optimised Bending Radius: The cables are engineered for high installation flexibility. For unarmored or shielded flexible cables, the allowable bending radius is not less than 6 times the cable's outer diameter.
Installation Requirements: It is recommended that the ambient temperature during installation be no lower than 0°C to maintain the mechanical integrity of the insulation layer.
Superior Insulation Stability: Under standard operating conditions, the product demonstrates exceptionally high insulation resistance and voltage endurance, significantly mitigating the risk of electrical failures.

Core Application Areas
Due to their excellent thermal and physical properties, this cable series is widely deployed in the following sectors:

Heat-Resistant Wiring Systems: Specifically designed for fixed wiring scenarios with high-temperature requirements, particularly where operating temperatures exceed 105°C.
Electrical and Electronic Connectivity: Widely used for both internal and external power transmission and signal connections in various electronic and electrical apparatus.
High-Standard Construction Projects: Thanks to its Low Smoke Zero Halogen (LSZH) properties, this series is the preferred choice for densely populated public areas, high-rise buildings, and industrial power distribution systems with rigorous fire safety standards.

Type and name of cable

Type

Name

WDZ-BYJ

Copper core halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated cable

WDZ-BYJ-105

Copper core 105 ℃ halogen-free low smoke positive flame irradiated cross-linked polyolefin insulated cable

WDZ-BYJ-125

Copper core 125 ℃ halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated cable

WDZ-BYJ-150

Copper core 150 ℃ halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated cable

WDZ-RYJ

Copper core halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated flexible cable

WDZ-RYJ-105

Copper core 105 ℃ halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated flexible cable

WDZ-RYJ-125

Copper core 125 ℃ halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated flexible cable

WDZ-RYJ-150

Copper core 150 ℃ halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated flexible cable

WDZ-BYJR

Copper core halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated flexible cable

WDZ-BYJR-105

Copper core 105 ℃ halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated flexible cable

WDZ-BYJR-125

Copper core 125 ℃ halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated flexible cable

WDZ-BYJR-150

Copper core 150 ℃ halogen-free low smoke flame-retardant irradiated cross-linked polyolefin insulated flexible cable


Specifications of cable

Type

Rated voltage

No. of cores

Nominal cross-sectional area mm²

WDZ-BYJ

300/500

1 

0.5~1

WDZ-BYJ

450/750

1 

1.5~400

WDZ-RYJ

300/500

1 

0.5~1

WDZ-RYJ

450/750

1 

15~240

WDZ-BYJR

300/500

1 

0.75~1

WDZ-BYJR

450/750

1 

1.5~240

FAQ

Q: In which fields are your company's products applied?

A: The products cover multiple fields including electric power, new energy, transportation, communications, and engineering. Custom XLPO Insulated Cable. The company has also continuously passed the qualification verification for power cables and conductors of the State Grid Corporation of China for many years.

Q: What is your company's production capacity?

A: Guanghuan Cable currently has a standardized production base and has built a full-chain industrial system covering R&D, production, and testing. XLPO Insulated Wire and Cable Manufacturer in China. It occupies an area of over 100,000 square meters with a building area of more than 45,000 square meters. The company owns over 70 advanced production and testing equipment lines, employs more than 140 staff, and achieves an annual output value exceeding 3 billion RMB.

Q: Has the company obtained relevant quality system certifications?

A: Yes. The company has obtained ISO9001 Quality Management System, ISO14001 Environmental Management System, ISO45001 Occupational Health and Safety Management System, and GB/T23331 Energy Management System certifications. It has also obtained the national compulsory CCC certification and the National Industrial Production License.

Q: What green and environmental certifications or initiatives does the company have?

A: The company has established an Environmental Management System, Energy Management System, Green Management System, and Social Responsibility Management System. As Cross-linked Polyolefin Insulated Cable Factory in China, it has completed product carbon footprint certification and obtained certifications such as "Green Manufacturing Enterprise," "China Energy-Saving and Environmental Protection Product," and "Carbon Neutrality Commitment Demonstration Unit."

Q: Does the company focus on technological innovation? What recent patent achievements have there been?

A: The company actively implements the strategy of "revitalizing the enterprise through science and technology" and continuously increases R&D investment. As of 2026, it has disclosed 45 patents, including an important patent for "a halogen-free flame-retardant environmentally friendly cable and its preparation method."

Q: Does the company have sales and service networks across the country?

A: Yes. The company has set up sales outlets or offices in many major cities across China, such as Nanjing, Shanghai, Beijing, Guangzhou, Shenzhen, and Inner Mongolia, responsible for marketing and product after-sales service.

CERTIFICATE DISPLAY
  • Energy Management System Certification Certificate
  • Product Certification
  • Product Certification
  • Product Certification
  • Zertifikat Certificate
  • Zertifikat Certificate
NEWS & INSIGHTS
Wuxi Guanghuan Cable Co., Ltd. Wuxi Guanghuan Cable Co., Ltd. View All News
  • Industry News
    Types of Cables Used in Subway Tunnels: A Complete Selection Guide for Metro Projects

    A subway tunnel is one of the harshest places to install an electrical cable. The space is confined, the atmosphere is humid and often chemically aggressive, maintenance access is limited to a few hours at night, and a single failure during service hours can strand thousands of ...

  • Industry News
    How to Calculate Cable Size: A Step-by-Step Guide for Safe, Real Projects

    Getting the conductor size right is one of those decisions that quietly determines whether an installation runs comfortably for thirty years or overheats in its first hot summer. An undersized cable wastes energy, shortens insulation life and creates a genuine fire risk; a cable...

  • Industry News
    Industrial Automation Cables: A Practical Guide to Types, Selection & Quality

    From robotic assembly cells to high-speed packaging lines, modern manufacturing depends on a network of cables that carry power, control signals, and data between machines. Industrial automation cables are the quiet workhorses behind automated production, and choosing the right ...

  • Industry News
    How to Calculate Cable Size: A Step-by-Step Guide for Electrical Projects

    Ask any experienced electrical engineer and you will hear the same thing: cable sizing is not one formula but a short chain of checks, and every link in that chain has to hold. Get the current right but ignore the derating factors, and the conductor runs hotter than its insulati...